| Note |
|
Water collection will be taken from three locations for Chemical and Microbiology analyses: SRV-K (hot water tap), SRV-K (cold
water tap) and SVO-ZV. The entire collection procedure will be completed for each tap before proceeding to remaining taps.
|
|
|
|
| 1. |
Unstow from Water Sampler and Archiver (WS&A): ISS Potable Water Collection Subpack (one), Sharpie Pen, Water Microbiology
Kit (WMK)
|
|
|
|
| Note |
| 1. |
SRV-K water: Turn SRV-K heater on before collecting water samples. Start sampling only after heating cycle is completed. Each
heating cycle requires 15 minutes for pasteurization of 525 mL of water. One delivery = 25 mL.
|
| 2. |
SVO-ZV: The hand pump may be used to provide sufficient pressure to permit water sample collection. There is no device for
accurate SVO-ZV water amount measurement. Crewmember will be required to perform visual estimation of 25 mL of flush water
and 100 mL and 125 mL samples by comparison to SRV-K samples.
|
|
|
| Caution |
|
To avoid contamination, use new potable water sampler for each tap.
|
|
|
|
| 1. |
Wipe appropriate tap SRV-K (SVO-ZV) with Disinfectant Wipe. Discard Wipe.
|
|
|
|
|
|
| 1. |
Remove one potable water sampler from Water Sampler & Archiver (WS&A) Subpack and remove from protective package.
|
|
| 2. |
Place potable water sampler package in WS&A.
|
|
|
|
| Caution |
| 1. |
To avoid sample contamination, do not touch SRV-K (SVO-ZV) tap. |
| 2. |
Hold potable water sampler by middle only. |
|
|
|
|
| 1. |
Put potable water sampler on SRV-K (SVO-ZV) tap.
|
|
|
|
|
|
| ATTACHING SMALL WASTE WATER BAG |
| 1. |
Unstow one Small Waste Water Bag from WS&A Subpack.
|
|
| 2. |
Remove cap from Small Waste Water Bag connection.
|
|
| 3. |
Attach the Small Waste Water Bag to potable water sampler, bag connection ↷.
|
|
|
|
|
|
| COLLECTING WATER INTO SMALL WASTE WATER (FLUSH) BAG |
| 1. |
Currently collecting from SRV-K (hot or cold)
|
|
| 2. |
Switch WATER QUANTITY mL → CONTINUOUS
|
|
| 3. |
Delivery valve (HOT or COLD) → OPEN
|
|
|
|
| 5. |
Push H2O DSPR Pump pb → ON
|
|
| 6. |
Place 25 mL of water (one cycle of dispenser) into Small Waste Water Bag (1/12 full).
|
|
| 7. |
Push H2O DSPR Pump pb → OFF when desired amount of H2O has been dispensed
|
|
| 8. |
Delivery valve (HOT or COLD) → CLOSE (after each portion collection)
|
|
| 9. |
Place 25 mL of water into Small Waste Water Bag (1/12 full).
|
|
|
|
| Note |
| 1. |
Do not remove Small Waste Water Bag until ready to connect TOC Water Sample Bag or Syringe. |
| 2. |
Do not perform collection into TOC Sample Syringe unless instructed to. |
|
|
|
|
| 1. |
Unstow Water Sample Bag or TOC Sample Syringe from WS&A Subpack.
|
|
|
|
|
|
| 1. |
Record date, time, and sampling location on Bag or Syringe. Label using Sharpie Pen.
|
|
|
|
| Caution |
|
Do not remove potable water sampler from port until all samples have been collected from that port.
|
|
|
|
| REMOVING SMALL WASTE WATER BAG |
| 1. |
Remove Small Waste Water Bag from potable water sampler, bag connection ↶.
|
|
| 2. |
Replace cap onto Small Waste Water Bag connection.
|
|
| 3. |
Place the Small Waste Water Bag into a small Ziploc Storage Bag.
|
|
| 4. |
Stow in Subpack (WS&A).
|
|
|
|
|
|
| ATTACHING TOC WATER SAMPLE BAG OR SYRINGE TO POTABLE WATER SAMPLER CONNECTION |
|
|
| 2. |
Remove cap from TOC Water Sample Bag connection.
|
|
| 3. |
Attach TOC Water Sample Bag to potable water sampler, bag connection ↷.
|
|
|
|
| Note |
|
Do not overfill bag. Overfilled bag may cause leakage.
|
|
| 5. |
Remove cap from TOC Sample Syringe connection.
|
|
| 6. |
Attach TOC Sample Syringe to potable water sampler, Syringe connection ↷.
|
|
|
|
| 8. |
OPEN SYRINGE SHUTOFF VALVE. Turn valve to position that is parallel to flow direction.
|
|
|
|
|
|
| COLLECTING WATER INTO TOC WATER SAMPLE BAG OR SYRINGE |
|
|
| 2. |
Collection from SRV-K (hot or cold)
|
|
| 3. |
Switch WATER QUANTITY mL → CONTINUOUS
|
|
| 4. |
Delivery valve (HOT or COLD) → OPEN
|
|
|
|
| 6. |
Push H2O DSPR Pump pb → ON
|
|
| 7. |
Place 100 mL of water (four deliveries) into TOC Water Sample Bag (1/3 full).
|
|
| 8. |
Push H2O DSPR Pump pb → OFF when desired amount of H2O has been dispensed
|
|
| 9. |
Delivery valve (HOT or COLD) → CLOSE (after each portion collection)
|
|
| 10. |
Place 100 mL of water into TOC Water Sample Bag (1/3 full).
|
|
| 11. |
Collecting from SRV-K (hot or cold)
|
|
| 12. |
Switch WATER QUANTITY mL → CONTINUOUS
|
|
| 13. |
Delivery valve (HOT or COLD) → OPEN
|
|
| 14. |
✓ DSPR RDY LED is lit
|
|
| 15. |
Push H2O DSPR Pump pb → ON
|
|
| Note |
|
Plunger is designed so that it cannot be withdrawn beyond 25 mL mark. Do not underfill Syringe.
|
|
| 16. |
Place 25 mL of water (one cycle of dispenser) into TOC Water Sample Syringe.
|
|
| 17. |
Push H2O DSPR Pump pb → OFF when desired amount of H2O has been dispensed
|
|
| 18. |
Delivery valve (HOT or COLD) → CLOSE (after each portion collection)
|
|
| 19. |
Turn Syringe vlv perpendicular to flow direction.
|
|
| Note |
|
Plunger is designed so that it cannot be withdrawn beyond 25 mL mark. Do not underfill Syringe.
|
|
| 20. |
Place 25 mL of water into TOC Sample Syringe.
|
|
| 21. |
Turn syringe valve perpendicular to flow direction.
|
|
|
|
| Note |
|
Do not remove TOC Water Sample Bag or Syringe until ready to connect Chemical Post-Flight Analysis Bag.
|
|
|
|
| 1. |
Unstow Chemical Sample Post-Flight Analysis Bag from WS&A Subpack.
|
|
| 2. |
Record date, time, and sampling location on Chemical Sample Post-Flight Analysis Bag Label using Sharpie Pen.
|
|
|
|
| Caution |
|
Do not remove potable water sampler from port until all samples have been collected from that port.
|
|
|
|
| REMOVING TOC WATER SAMPLE BAG OR SYRINGE/ATTACHING CHEMICAL SAMPLE POST-FLIGHT ANALYSIS BAG |
|
|
| 2. |
Remove TOC Water Sample Bag from potable water sampler, bag connection ↶.
|
|
|
|
| 4. |
Remove cap from Chemical Sample Post-Flight Analysis Bag connection
|
|
| 5. |
Attach Chemical Sample Post-Flight Analysis Bag to water potable water sampler, bag connection ↷.
|
|
| 6. |
Place TOC Water Sample Bag into small Ziploc Storage Bag.
|
|
| 7. |
Temporary stow Sample Bag in WS&A
|
|
| 8. |
Remove TOC Sample Syringe from potable water sampler, bag connection ↶.
|
|
| 9. |
Replace cap on syringe connection.
|
|
| 10. |
Attach Chemical Sample Post-Flight Analysis Bag to water potable water sampler, bag connection ↷.
|
|
| 11. |
Replace cap on syringe connection.
|
|
| 12. |
Place Syringe into small Ziploc Storage Bag.
|
|
| 13. |
Temporary stow in WS&A.
|
|
|
|
|
|
| COLLECTING WATER INTO CHEMICAL SAMPLE POST-FLIGHT ANALYSIS BAG |
| 1. |
Currently collecting from SRV-K (hot or cold)
|
|
| 2. |
Switch WATER QUANTITY mL → CONTINUOUS
|
|
| 3. |
Delivery valve (HOT or COLD) → OPEN
|
|
|
|
| 5. |
Push H2O DSPR Pump pb → ON
|
|
| 6. |
Place 750 mL of water (30 deliveries) into Chemical Sample Post-Flight Analysis Bag (3/4 full).
|
|
| 7. |
Push H2O DSPR Pump pb → OFF when desired amount of H2O has been dispensed
|
|
| 8. |
Delivery valve (HOT or COLD) → CLOSE (after each portion collection)
|
|
| 9. |
Place 750 mL of water into Chemical Sample Post-Flight Analysis Bag (3/4 full).
|
|
|
|
| Note |
|
Do not remove Chemical Sample Post-Flight Analysis Bag until ready to connect Micro-Sample In-Flight Analysis Bag.
|
|
|
|
| 1. |
Unstow Micro-Sample In-Flight Analysis Bag from WMK Subpack.
|
|
| 2. |
Record date and circle sampling location on Micro-Sample In-Flight Analysis Bag using Sharpie Pen.
|
|
|
|
| Caution |
|
Do not remove potable water sampler from port until all samples have been collected from that port.
|
|
|
|
| REMOVING CHEMICAL SAMPLE POST-FLIGHT ANALYSIS BAG |
| 1. |
Remove Chemical Sample Post-Flight Analysis Bag from potable water sampler, bag connection ↶.
|
|
|
|
| 3. |
Place bag into large Ziploc Storage Bag.
|
|
| 4. |
Temporary stow bag in TBD.
|
|
|
|
|
|
| ATTACHING MICRO-SAMPLE IN-FLIGHT ANALYSIS BAG |
| 1. |
Remove cap from Micro-Sample In-Flight Analysis Bag.
|
|
| 2. |
Attach Micro-Sample In-Flight Analysis Bag to potable water sampler, bag connection ↷.
|
|
|
|
| Note |
|
Do not overfill bag. Overfilled bag may cause leakage.
|
|
|
|
| COLLECTING WATER INTO MICRO-SAMPLE IN-FLIGHT ANALYSIS BAG |
| 1. |
Currently collecting from SRV-K (hot or cold)
|
|
| 2. |
Switch WATER QUANTITY mL → CONTINUOUS
|
|
| 3. |
Delivery valve (HOT or COLD) → OPEN
|
|
|
|
| 5. |
Push H2O DSPR Pump pb → ON
|
|
| 6. |
Place 125 mL of water (five deliveries) into Micro-Sample In-Flight Bag (3/4 full).
|
|
| 7. |
Push H2O DSPR Pump pb → OFF when desired amount of H2O has been dispensed
|
|
| 8. |
Delivery valve (HOT or COLD) → CLOSE (after each portion collection)
|
|
| 9. |
Place 125 mL of water into Micro-Sample In-Flight Bag (1/2 full).
|
|
|
|
| Note |
|
Do not remove Micro-Sample In-Flight Analysis Bag until ready to connect Micro-Sample Post-Flight Analysis Bag.
|
|
|
|
| 1. |
Unstow Micro-Sample Post-Flight Analysis Bag from WMK Subpack.
|
|
| 2. |
Record date and circle sampling location on Bag using Sharpie Pen.
|
|
|
|
| Caution |
|
Do not remove potable water sampler from port until all samples have been collected from that port.
|
|
|
|
| REMOVING MICRO-SAMPLE IN-FLIGHT ANALYSIS BAG |
| 1. |
Remove Micro-Sample In-Flight Analysis Bag from potable water sampler, bag connection ↶.
|
|
| 2. |
Replace cap on bag connection.
|
|
| 3. |
Temporary stow bag in WMK.
|
|
|
|
|
|
| 1. |
Remove cap from Micro-Sample Post-Flight Analysis Bag.
|
|
| 2. |
Attach Micro-Sample Post-Flight Analysis Bag to water sampler, bag connection ↷.
|
|
|
|
|
|
| COLLECTING WATER INTO MICRO-SAMPLE POST-FLIGHT ANALYSIS BAG |
| 1. |
Currently collecting from SRV-K (hot or cold)
|
|
| 2. |
Switch WATER QUANTITY mL → CONTINUOUS
|
|
| 3. |
Delivery valve (HOT or COLD) → OPEN
|
|
|
|
| 5. |
Push H2O DSPR Pump pb → ON
|
|
| 6. |
Place 1000 mL of water (40 deliveries) into Micro-Sample Post-Flight Bag (full).
|
|
| 7. |
Push H2O DSPR Pump pb → OFF when desired amount of H2O has been dispensed
|
|
| 8. |
Delivery valve (HOT or COLD) → CLOSE (after each portion collection)
|
|
| 9. |
Place 1000 mL of water into Micro-Sample Post-Flight Bag (full).
|
|
|
|
|
|
| REMOVING MICRO-SAMPLE POST-FLIGHT ANALYSIS BAG |
| 1. |
Remove Micro-Sample Post-Flight Analysis Bag from potable water sampler, bag connection ↶.
|
|
|
|
| 3. |
Place bag into large Ziploc Storage Bag (from WMK Subpack).
|
|
| 4. |
Temporary stow bag in WMK.
|
|
|
|
|
|
| 1. |
Remove potable water sampler from SRV-K (SVO-ZV) tap.
|
|
|
|
|
|
| 1. |
Place potable water sampler into small Ziploc Storage Bag. Place in WS&A Subpack.
|
|
|
|
|
|
| 1. |
Are there still other ports requiring sampling ?
|
|
|
|
|
|
| 1. |
Place Subpack into WS&A
|
|
|
|
|
|
|
1
Water Collection Order - Chemical and Micro In-Flight and Post-Flight
(photo)
|
|
2
Small Waste Water Bag
(photo)
|
|
3
TOC Water Sample Bag
(photo)
|
|
4
Chemical Sample Post-Flight Analysis Bag
(photo)
|
|
5
Micro-Sample In-Flight Analysis Bag
(photo)
|
|
6
Micro-Sample Post-Flight Analysis Bag
(photo)
|